Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Heart Rhythm ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38574791

RESUMO

BACKGROUND: One common mode of lead failure is insulation breach which may result in myopotential noise and device malfunction. "Pseudo-unipolarization" of bipolar pacing stimuli, as observed from a routine 12-lead ECG due to stimulus current leak has been observed with insulation breaches. OBJECTIVE: We sought to characterize this ECG finding to detect lead this type of lead malfunction. METHODS: 138 transvenous leads were analyzed, including 88 with known malfunction and 50 normal leads. The amplitude of a bipolar pacing stimulus on ECG was recorded and compared to a control dataset of newly implanted leads with bipolar stimuli normalized for output. RESULTS: The malfunction group consisted of 61% RA and 39% RV leads with mean pacing output 2.74V at 0.5ms. There was a significant difference in ECG bipolar stimulus amplitudes at time of identification of failure (7.89 ± 7.56mm per V, p<0.001) compared to those of normal leads (0.86 ± 0.41mm per V). ROC curve for the prediction of lead malfunction based on absolute EKG amplitude displayed an area under curve of 0.93 (95% CI 0.891- 0.969). When normalized for programmed stimulus output, a cutoff of 5mm/V demonstrated a sensitivity of 91% and a specificity of 92% (AUC 0.967 95% CI 0.938-0.996). CONCLUSION: The maximum amplitude of a bipolar pacing stimulus on ECG is significantly lower in normal functioning leads compared to those with known malfunction. This simply-derived variable demonstrated good accuracy at identifying lead failure due to insulation breach.

2.
Med Clin North Am ; 108(3): 455-468, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38548457

RESUMO

Chronic coronary disease (CCD) is a major cause of morbidity and mortality worldwide. The most common symptom of CCD is exertional angina pectoris, a discomfort in the chest that commonly occurs during activities of daily life. Patients are dismayed by recurring episodes of angina and seek medical help in preventing or minimizing episodes. Angina occurs when the coronary arteries are unable to supply sufficient blood flow to the cardiac muscle to meet the metabolic needs of the left ventricular myocardium. While lifestyle changes and aggressive risk factor modification play a critical role in the management of CCD, management of angina usually requires pharmacologic therapy. Medications such as beta-blockers, calcium channel blockers, nitrates, ranolazine, and others ultimately work to improve the mismatch between myocardial blood flow and metabolic demand. This manuscript briefly describes the pathophysiologic basis for symptoms of angina, and how currently available anti-anginal therapies contribute to preventing or minimize the occurrence of angina.


Assuntos
Isquemia Miocárdica , Humanos , Isquemia Miocárdica/tratamento farmacológico , Isquemia Miocárdica/diagnóstico , Angina Pectoris/tratamento farmacológico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Ranolazina/uso terapêutico , Antagonistas Adrenérgicos beta/uso terapêutico
3.
Heart Rhythm ; 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38437891

RESUMO

BACKGROUND: Human in vivo data on the chemical stability of different transvenous lead materials, particularly OptimTM leads, are lacking. OBJECTIVES: The purpose of this study was to determine the chemical reactivity of insulation materials by analyzing the molar mass of extracted pacing and defibrillator leads METHODS: We collected extracted leads at Emory University Hospitals and sent the leads with thermoplastic outer insulation material for molar mass analysis, a material characteristic that informs biostability. Leads were separated based on the chemical identity of the outer insulation material, and the molar mass was measured by an independent party. The extent of chemical reaction was compared across leads having different materials: poly(ether)urethane 55D, poly(ether)urethane 80A, and Optim. RESULTS: A total of 70 leads were extracted. The subset of extracted leads having outer insulation materials composed of PEU or Optim were analyzed for molar mass, where implant times ranged from 0.12 to 16.26 years. The rate of chemical degradation was compared by plotting the extent of reaction [Mn(t = 0)/Mn(t)] as a function of implant time. The Optim molar mass decreased to 40% of its initial value at 10 years of implant. No change in the molar mass of the PEU insulations could be resolved over the same 10-year implant time. CONCLUSION: Because the molar mass of a polymer is directly related to its mechanical integrity, the observed decrease in molar mass of Optim likely translates into premature insulation defects and is consistent with the observed increased rate of electrical malfunction/noise in this subset of cardiac leads.

4.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38450808

RESUMO

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Assuntos
Remoção de Dispositivo , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico , Masculino , Feminino , Remoção de Dispositivo/efeitos adversos , Idoso , Resultado do Tratamento , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Desfibriladores Implantáveis , Fatores de Tempo , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização Cardíaca
5.
Curr Cardiol Rep ; 25(12): 1811-1821, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38079057

RESUMO

PURPOSE OF REVIEW: Patients with established coronary artery disease (CAD) are at high residual risk for adverse events, despite guideline-based treatments. Herein, we aimed to determine whether risk scores based on multiple circulating biomarkers that represent activation of various pathophysiologically important pathways involved in atherosclerosis and myocardial dysfunction help identify those at greatest residual risk. RECENT FINDINGS: Numerous circulating proteins, representing dysregulation of the pathways involved in the development and stability of coronary and myocardial diseases, have been identified. When aggregated together, biomarker risk scores (BRS) more accurately stratify patients with established CAD that may help target interventions in those individuals who are at elevated risk. Moreover, intensification of guideline-based therapies has been associated with parallel improvements in both BRS and outcomes, indicating that these risk scores may be employed clinically to target therapy. Multi-protein BRS are predictive of risk, independent of, and in addition to traditional risk factor assessments in patients with CAD. Those with elevated risk may benefit from optimization of therapies, and improvements in the BRS will identify those with improved outcomes.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Proteômica , Valor Preditivo dos Testes , Fatores de Risco , Biomarcadores
6.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38000900

RESUMO

AIMS: Single-connector (DF4) defibrillator leads have become the predominantly implanted transvenous implantable cardioverter-defibrillator lead. However, data on their long-term performance are derived predominantly from manufacturer product performance reports. METHODS AND RESULTS: We reviewed medical records in 5289 patients with DF4 leads between 2011 and 2023 to determine the frequency of lead-related abnormalities. We defined malfunction as any single or combination of electrical abnormalities requiring revision including a sudden increase (≥2×) in stimulation threshold, a discrete jump in high-voltage impedance, or sensing of non-physiologic intervals or noise. We documented time to failure, predictors of failure, and management strategies. Mean follow-up after implant was 4.15 ± 3.6 years (median = 3.63), with 37% of leads followed for >5 years. A total of 80 (1.5%) leads demonstrated electrical abnormalities requiring revision with an average time to failure of 4 ± 2.8 years (median = 3.5). Of the leads that malfunctioned, 62/80 (78%) were extracted and replaced with a new lead and in the other 18 cases, malfunctioned DF4 leads were abandoned, and a new lead implanted. In multivariable models, younger age at implant (OR 1.03 per year; P < 0.001) and the presence of Abbott/St. Jude leads increased the risk of malfunction. CONCLUSION: DF4 defibrillator leads demonstrate excellent longevity with >98.3% of leads followed for at least 5 years still functioning normally. Younger age at implant and lead manufacturer are associated with an increased risk of DF4 lead malfunction. The differences in lead survival between manufacturers require further investigation.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Falha de Equipamento , Estudos Retrospectivos
7.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37702135

RESUMO

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
8.
Circ Arrhythm Electrophysiol ; 16(8): 468-474, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37485688

RESUMO

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICDs) are an attractive alternative to transvenous ICDs among those not requiring pacing. However, the risks of damage to the S-ICD electrode during sternotomy and adverse interactions with sternal wires remain unclear. We sought to determine the rates of damage to the S-ICD lead during sternotomy, inappropriate shocks from electrical noise due to interaction with sternal wires, and failure to terminate spontaneous or induced ventricular arrhythmias. METHODS: Retrospective, multicenter study of patients undergoing sternotomy before or after S-ICD implantation. Clinical, procedural, and device-related data were collected by each center and analyzed by the coordinating center. These data were compared with a historical control cohort of nonsternotomy patients. RESULTS: Of 196 identified patients (52±16 years, 47 women), 166 underwent S-ICD implantation after sternotomy and 30 sternotomy after S-ICD. There was no damage to any lead among those who underwent sternotomy after S-ICD. Defibrillation threshold testing was performed in 63% at implant, with 91% first shock success. During a median follow-up of 29 months (range, 1-188), S-ICD first shocks successfully terminated spontaneous ventricular arrhythmias in 31 of 32 patients (97%). Inappropriate shocks occurred in 22 patients, most commonly related to T wave oversensing (n=14). Compared with the nonsternotomy controls, there were no differences in rates of first shock success for induced or spontaneous arrhythmias or rate of inappropriate shocks. CONCLUSIONS: Sternotomy before or after S-ICD does not confer additional risk relative to a historical control group without sternotomy.


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Desfibriladores Implantáveis/efeitos adversos , Esternotomia/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
9.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1172-1180, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36898953

RESUMO

BACKGROUND: Class IC antiarrhythmic agents are effective for treating atrial tachyarrhythmias, but their use is restricted in patients with coronary artery disease (CAD). Data on the safety of the use of IC agents in patients with CAD in the absence of recent acute coronary syndromes are lacking. OBJECTIVES: This study sought to evaluate the safety and feasibility of treatment with IC agents in patients with varying degrees of CAD in a large serial, real-world cohort. METHODS: We retrospectively identified all patients at our institution from January 2005 to February 2021 on a IC agent (n = 3,445) and those on sotalol or dofetilide (n = 2,216) as controls, excluding those with a prior history of ventricular tachycardia, implantable cardioverter-defibrillator placement, or nonrevascularized myocardial infarction. Baseline clinical characteristics included degree of CAD (categorized as none, nonobstructive, or obstructive), other comorbid illness, and medication use. Clinical outcomes, including survival, were ascertained. We performed Cox regression analysis to evaluate the effect of IC use on event-free survival across varying degrees of CAD. RESULTS: After adjustment for baseline characteristics, there was an independent association between IC use and improved mortality. However, there was an interaction between IC use and degree of CAD (compared to sotalol) demonstrating poorer event-free survival among those with obstructive coronary disease (HR: 3.80; 95% CI: 1.67-8.67; P = 0.002). CONCLUSIONS: Among select patients with nonobstructive CAD and without a history of ventricular tachycardia, IC agents are not associated with increased mortality. Therefore, these agents may be an option for some patients in whom they are frequently restricted. Further prospective studies are warranted.


Assuntos
Doença da Artéria Coronariana , Taquicardia Ventricular , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/tratamento farmacológico , Flecainida/efeitos adversos , Sotalol/uso terapêutico , Estudos Retrospectivos , Estudos de Viabilidade , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/complicações
10.
J Clin Epidemiol ; 156: 11-21, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36764466

RESUMO

OBJECTIVES: The objectives of this study are to describe the characteristics of living systematic reviews (LSRs) and to understand their life cycles. STUDY DESIGN AND SETTING: We conducted a comprehensive search up to April 2021 then selected articles and abstracted data in duplicate and independently. We undertook descriptive analyses and calculated delay in version update and delay since the last published version. RESULTS: We included 76 eligible LSRs with a total of 279 eligible versions. The majority of LSRs was from the clinical field (70%), was COVID-19 related (63%), and had a funding source specified (62%). The median number of versions per LSR was 2 (interquartile range (IQR) 1-4; range 1-19). The median and IQR for the ratio of the actual period of update to the planned period of update was 1.12 (0.81; 1.71). Out of all reviews with a 'planned period of update' and at least one update (N = 19), eight LSRs (42%) had a period since last published version greater than 3 times the planned period of update. No LSR included a 'retirement notice' in their latest published version. CONCLUSION: While most LSR complied with the planned period of producing updates, a substantive proportion lagged since their last update.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Inquéritos e Questionários , Revisões Sistemáticas como Assunto
12.
Cureus ; 15(12): e50918, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38249221

RESUMO

The monkeypox (mpox) outbreak that began in May 2022 spread globally with a wide range of presentations. Mpox proctitis has been recognized as one of the severe forms of the virus during this outbreak. We present the case of a 33-year-old male with well-controlled HIV engaging in receptive anal intercourse presented with profuse rectal bleeding, tenesmus, and anal pain in July 2022. His symptoms persisted despite treatment for his rectal chlamydia with doxycycline. Rectal imaging with computed tomography demonstrated impressive inflammation. Contrast-enhanced images highlighted rectal wall thickening and submucosal edema. Diffuse lymphadenopathy of the anorectal region was also clearly seen. He received symptomatic treatment with tecovirimat resulting in the resolution of his symptoms and complaints. Subsequent rectal imaging displayed improvement and decreased inflammation. A better understanding of various presentations, imaging characteristics, and management is necessary to curb further dissemination.

14.
Curr Cardiol Rep ; 24(10): 1233-1240, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35951261

RESUMO

PURPOSE OF REVIEW: Leadless pacemakers (LPs) are emerging as alternative cardiac implantable devices for the treatment of bradyarrhythmia. This article aims to review the data behind the safety and efficacy of these devices while highlighting their pros and cons. RECENT FINDINGS: Prospective non-randomized studies and registries have found that LPs are associated with lower rate of device-related complications mainly driven by lower need for lead-related interventions as compared to traditional pacemakers. On the other hand, cardiac perforation appears to occur more frequently with LPs. LPs are associated with lower rate of device-related complications as compared to the traditional pacemakers. However, the rate of pericardial effusion is higher and is more severe. As we transition to multi-chamber LPs, it is important to ensure the safety and efficacy of these devices.


Assuntos
Marca-Passo Artificial , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Desenho de Equipamento , Humanos , Lipopolissacarídeos , Estudos Prospectivos , Resultado do Tratamento
16.
Ann Surg ; 275(2): 398-405, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34967201

RESUMO

OBJECTIVE: This multicenter study aims to describe the injury patterns, emergency management and outcomes of the blast victims, recognize the gaps in hospital disaster preparedness, and identify lessons to be learned. SUMMARY BACKGROUND DATA: On August 4th, 2020, the city of Beirut, Lebanon suffered the largest urban explosion since Hiroshima and Nagasaki, resulting in hundreds of deaths and thousands of injuries. METHODS: All injured patients admitted to four of the largest Beirut hospitals within 72 hours of the blast, including those who died on arrival or in the emergency department (ED), were included. Medical records were systematically reviewed for: patient demographics and comorbidities; injury severity and characteristics; prehospital, ED, operative, and inpatient interventions; and outcomes at hospital discharge. Lessons learned are also shared. RESULTS: An estimated total of 1818 patients were included, of which 30 died on arrival or in the ED and 315 were admitted to the hospital. Among admitted patients, the mean age was 44.7 years (range: 1 week-93 years), 44.4% were female, and the median injury severity score (ISS) was 10 (5, 17). ISS was inversely related to the distance from the blast epicenter (r = --0.18, P = 0.035). Most injuries involved the upper extremities (53.7%), face (42.2%), and head (40.3%). Mildly injured (ISS <9) patients overwhelmed the ED in the first 2 hours; from hour 2 to hour 8 post-injury, the number of moderately, severely, and profoundly injured patients increased by 127%, 25% and 17%, respectively. A total of 475 operative procedures were performed in 239 patients, most commonly soft tissue debridement or repair (119 patients, 49.8%), limb fracture fixation (107, 44.8%), and tendon repair (56, 23.4%). A total of 11 patients (3.5%) died during the hospitalization, 56 (17.8%) developed at least 1 complication, and 51 (16.2%) were discharged with documented long-term disability. Main lessons learned included: the importance of having key hospital functions (eg, laboratory, operating room) underground; the nonadaptability of electronic medical records to disasters; the ED overwhelming with mild injuries, delay in arrival of the severely injured; and the need for realistic disaster drills. CONCLUSIONS: We, therefore, describe the injury patterns, emergency flow and trauma outcome of patients injured in the Beirut port explosion. The clinical and system-level lessons learned can help prepare for the next disaster.


Assuntos
Traumatismos por Explosões/epidemiologia , Traumatismos por Explosões/terapia , Explosões , Hospitalização/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Traumatismos por Explosões/etiologia , Criança , Pré-Escolar , Defesa Civil , Tratamento de Emergência , Feminino , Hospitais , Humanos , Lactente , Líbano , Masculino , Pessoa de Meia-Idade , Adulto Jovem
17.
Front Cardiovasc Med ; 7: 613271, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33344519

RESUMO

Atrial fibrillation (AF) and cardiometabolic syndrome (CMS) have been linked to inflammation and fibrosis. However, it is still unknown which inflammatory cytokines contribute to the pathogenesis of AF. Furthermore, cardiometabolic syndrome (CMS) risk factors such as obesity, hypertension, insulin resistance/glucose intolerance are also associated with inflammation and increased level of cytokines and adipokines. We hypothesized that the inflammatory immune response is exacerbated in patients with both AF and CMS compared to either AF or CMS alone. We investigated inflammatory cytokines and fibrotic markers as well as cytokine genetic profiles in patients with lone AF and CMS. CMS, lone AF patients, patients with both lone AF and CMS, and control patients were recruited. Genetic polymorphisms in inflammatory and fibrotic markers were assessed. Serum levels of connective tissue growth factor (CTGF) were tested along with other inflammatory markers including platelet-to-lymphocyte ratio (PLR), monocyte-to-HDL ratio (MHR) in three groups of AF+CMS, AF, and CMS patients. There was a trend in the CTGF levels for statistical significance between the AF and AF+CMS group (P = 0.084). Genotyping showed high percentages of patients in all groups with high secretor genotypes of Interleukin-6 (IL-6) (P = 0.037). Genotyping of IFN-γ and IL-10 at high level showed an increase in expression in the AF + CMS group compared to AF and CMS alone suggesting an imbalance between the inflammatory and anti-inflammatory cytokines which is exacerbated by AF. Serum cytokine inflammatory cytokine levels showed that IL-4, IL-5, IL-10, IL-17F, and IL-22 were significant between the AF, AF+CMS, and CMS patients. Combination of both CMS and AF may be associated with a higher degree of inflammation than what is seen in either CMS or AF alone. Thus, the identification of a biomarker capable of identifying metabolic syndrome associated with disease will help in identification of a therapeutic target in treating this devastating disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...